CW Magnetron GLCWM-75L

 

 

GLCWM-75L Parameter
Operating Frequency………………………………………………………….915MH z /896MH z/922MH
Output…………………………………………………………………………………75Kw
magnetic field……………………………………………………………………...electromagnet
Output mode……………………………………………………………………….975 wave-guide
Anode cooling……………………………………………………………………..Cooling Water
Output window cooling………………………………………………………….Cooling air
Cathode cooling……………………………………………………………………Cooling air
Ring……………………………………………………………………………………...Required
commonly parameter
Cathode heated mode…………………………………………………………..Direct heating type
Filament Voltage……………………………………………………………………12.6V
Filament Current…………………………………………………………………….12A
Filament surge Current……………………………………………………………250( Max ) A
Size of outline……………………………………………………………………….. .see the outline drawing
Weight……………………………………………………………………………………..7Kg
Limits
MinMax
Filament Current..……………………….110A120A
Filament surge Current.……………….—-250A
Anode Voltage.……………………………—-18kV
Anode Current.…………………………..2A6A
Output power…………………………….—-108kW
Cooling Water temperature………….—-50˚C
Typical Operation
Electromagnet Current………………………………………………………………..5.0A
Filament Voltage…………………………………………………………………………9.5V
Filament Current………………………………………………………………………….85A
Anode Current……………………………………………………………………………..5.0A
Anode Voltage…………………………………………………………………………….17kV
Output Power……………………………………………………………………………….75kW