AC Contactor

 

 

 

 

CKJ11 SERİES

Type Rated Current
(A)
Rated Voltage
(KV)
Rated Making Capacity
(A)
Rated Breaking Capacity(A) Mechanical Life
(Million times)
Electrical Life
(Million times)
.pdf
Download
CKJ11-160/1.5 160 1.5 1600 1280 1 6
CKJ11-250-1.5 250 1.5 2500 2000 1 6
CKJ11-400/1.5 400 1.5 4000 3200 1 6
CKJ11-800/1.5 800 1.5 8000 6400 1 6
CKJ11-3000 3000 1.5 30000 24000 1 6
CKJ11-500/3.6 500 3.6 5000 4000 1 6
CKJ11-630/3.6 630 3.6 6300 5000 1 6

CHV SERİES

GL Type Rated Current
(A)
Rated Voltage
(KV)
Rated Making Capacity
(A)
Rated Breaking Capacity(A) Mechanical Life
(Million times)
Electrical Life
(Million times)
pdf
Download
CHV-400/3.3 400 3.3 4000 3200 1 6
CHV-450/3.6 450 3.6 4500 3600 0.3 6
CHV-450/1.14 450 1.14 4500 3600 0.3 6

CKJ5 SERİES

Type Rated Current
(A)
Rated Voltage
(KV)
Rated Making Capacity
(A)
Limited Breaking Capacity
(A)
Mechanical Life
(Million times)
Electrical Life
(Million times)
.pdf
Download
CKJ5-80/1.14 80 1.14 980 800 1 6
CKJ5-125/1.14 125 1.14 1500 1250 1 6
CKJ5-160/1.14 160 1.14 1600 1280 1 6
CKJ5-250/1.14 250 1.14 2500 2000 1 6
CKJ5-400/1.14 400 1.14 4000 3200 1 6
CKJ5-630/1.14 630 1.14 6300 5000 1 6

7.2KV SERİES

GL Type Rated Current
(A)
Rated Current
(A)
Rated Making Capacity
(A)
Rated Breaking Capacity(A) Mechanical Life
(Million times)
Electrical Life
(Million times)
pdf
Download
JCZ5-160/7.2kv 160 7.2 1600 1600 0.5 10
JCZ5-160/7.2kv 160 7.2 1600 1600 0.5 10
CKG4-160/7.2kv 160 7.2 1600 1600 0.5 10
CKTB50/25/63 160 7.2 1600 1600 0.5 10
CKG4-160/7.2kv 250 7.2 2500 2500 0.5 10
JCZ5-250/7.2kv 250 7.2 2500 2500 0.5 10
JCZ5-250/7.2kv 250 7.2 2500 2500 0.5 10
CKG4-250/7.2kv 250 7.2 2500 2500 0.5 10
CKG4-250/7.2kv 400 7.2 4000 4000 0.5 10
JCZ5-400/7.2kv 400 7.2 4000 4000 0.5 10
JCZ5-400/7.2kv 400 7.2 4000 4000 0.5 10
CKG4-400/7.2kv 400 7.2 4000 4000 0.5 10
JCZ5-630/7.2kv 630 7.2 6300 6300 0.5 10
JCZ5-630/7.2kv 630 7.2 6300 6300 0.5 10
CKG4-630/7.2kv 630 7.2 6300 6300 0.5 10

12KV SERİES

GL Type Rated Current
(A)
Rated Current
(A)
Rated Making Capacity
(A)
Limited Breaking Capacity
(A)
Mechanical Life
(Million times)
Electrical Life
(Million times)
pdf
Download
JCZ5-160/12kv 160 12 1600 1600 0.5 10
JCZ5-250/12kv 250 12 2500 2500 0.5 10
JCZ5-400/12kv 400 12 4000 4000 0.5 10
JCZ5-630/12kv 630 12 6300 6300 0.5 10
JCZ5-160/12kv 160 12 1600 1600 0.5 10
JCZ5-250/12kv 250 12 2500 2500 0.5 10
JCZ5-400/12kv 400 12 4000 4000 0.5 10
JCZ5-630/12kv 630 12 6300 6300 0.5 10
CKG4-160/12kv 160 12 1600 1600 0.5 10
CKG4-250/12kv 250 12 2500 2500 0.5 10
CKG4-400/12kv 400 12 4000 4000 0.5 10
CKG4-630/12kv 630 12 6300 6300 0.5 10
CKG4-160/12kv 160 12 1600 1600 0.5 10
CKG4-250/12kv 250 12 2500 2500 0.5 10
CKG4-400/12kv 400 12 4000 4000 0.5 10