By Contact Type
By Contact Voltage
We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.
The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ...
Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.
Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.
Thermal (Inverse Time) Trip Mechanism.
The thermal trip mechanism operates in response to overload conditions. The mechanism includes a bimetal element located behind the trip bar. The bimetal element is part of the current-carrying path. When there is an overload, the increased current flow heats the bimetal and causes it to bend. As the bimetal bends, it touches and rotates the trip bar causing the circuit breaker to trip. The time needed for the bimetal to bend and trip the circuit breaker varies inversely with the current.
Magnetic (Instantaneous) Trip Mechanism.
The magnetic trip mechanism operates when there is a high current (short circuit) in the current path. The mechanism includes an electromagnet and an armature. When high-level current passes through the conductor, the magnetic field strength of the electromagnet rapidly increases and attracts the armature. As the top of the armature is drawn to the electromagnet, the armature rotates the trip bar causing the circuit breaker to trip.
Özellikler:
Type | Poles | Terminals | kA@ | No. of Interphase Barriers | Rating (A) | |
415 V | 525 V | |||||
G15D | 3 | G1 | 15 | 15 | 2 | 16, 20, 32, 40, 50, 63 |
G1 | 15 | 15 | 80, 100 | |||
G1 | 15 | 15 | 125 | |||
F15D | 3 | G1 | 15 | 15 | 4 | 150, 160 |
G1 | 15 | 15 | 175, 200, 225 | |||
G4B | 15 | 15 | 250 | |||
G25D | 3 | G1 | 25 | 18 | 2 | 16, 20, 32, 40, 50, 63 |
G1 | 25 | 18 | 80, 100 | |||
G1 | 25 | 18 | 125 | |||
F25D | 3 | G1 | 25 | 22 | 4 | 150, 160 |
G1 | 25 | 22 | 175, 200, 225 | |||
G4B | 25 | 22 | 250 | |||
G35D | 3 | G1 | 35 | 22 | 2 | 16, 20, 32, 40, 50, 63 |
G1 | 35 | 22 | 80, 100 | |||
F35D | 3 | G1 | 35 | 22 | 4 | 125 |
G1 | 35 | 30 | 150, 160 | |||
G1 | 35 | 30 | 175, 200, 225 | |||
G4B | 35 | 30 | 250 | |||
F65DV | 3 | G1 | 65 | 35 | 4 | 20-25, 32-40, 45-63 |
G1 | 65 | 35 | 70-100 | |||
G1 | 65 | 35 | 90-125 | |||
G1 | 65 | 35 | 125-160 | |||
G4B | 65 | 35 | 175-250 |
Type | Poles | Terminal | k@ | No. of Interphase Barriers | Rating (A) | ||
415 V | 500 V | 525 V | |||||
K25D | 3 | G4B | 25 | 22 | - | 4 | 250 |
3 | G4B | 25 | 22 | - | 4 | 300, 350, 400 | |
K35D | 3 | G4B | 35 | 30 | 30 | 4 | 250 |
3 | G4B | 35 | 30 | 30 | 4 | 300, 350, 400 | |
3 | G4B | 36 | 22 | - | 4 | 500, 630 | |
K50D | 3 | G4B | 50 | 40 | 35 | 4 | 500, 630 |
Type | Poles | Terminal | k@ | No. of Interphase Barriers | Rating (A) | ||
415 V | 500 V | 525 V | |||||
K35DE | 3 | G4B | 35 | 30 | 30 | 4 | 200-400 |
K50DE | 3 | G4B | 50 | 40 | 35 | 4 | 300-630 |
K65DE | 3 | G4B | 65 | 50 | 50 | 4 | 200-400 |
K70DE | 3 | G4B | 70 | 50 | - | 4 | 300-630 |
Type | Poles | Terminals | kA@ | No. of Interphase Barriers | Rating (A) | |
415 V | 500 V | |||||
N83DE | 3 | G4B | 85++ | 65++ | 2 | 500-1000 |
3 | 2 | 600-1250 | ||||
3 | 2 | 800-1600 |
Tek bir sonuç gösteriliyor