GFP 400, High Voltage 1000Vdc, 400 Amp DC Passive Fuses + DC Contactor
High Voltage, Battery Disconnect with Passive Function.
Product Specification |
||
Specification | Unit | Data |
Rated Voltage | Volts | 1000 |
Continuous Current Rating at 85C | Amps | 400 |
Max Interrupt Current at 1000V & 27µH | Amps | 10000 |
Max Resistance before opening | mΩ | .150 |
Max Clear Time | mS | 3 |
Operating Temperature | C | -40 to +85 |
Storage Temperature | C | -40 to +125 |
Weight | Grams | 805 |
Triggering Current Tolerance | Amps | +/- 150 |
Minimum Dielectric After Trigger | MΩ | 5 |
Railway and Metro system, Energy Storage System, Electric Vehicles, Two-wheeled & Three wheeled electric motorcycles and bicycles, Automated Guided Vehicles, Aerospace Devices, Civil ships and Military ships, Power Electronics system of industrial automation equipment and industrial communications Equipment such as satellites and radars ect.
PART NUMBER SYSTEM | |
Part Number | Trip Current (AMP) |
GFP410 | 1000 |
GFP415 | 1500 |
GFP420 | 2000 |
GFP425 | 2500 |
Order Code Example: GFP410,1000A